Portable TDL Laser Ammonia Analyzer EDK 6900P series


Overview

The EDK series products employ Enhanced TDLAS(Tunable Diode Laser Absorption Spectroscopy) technology with 0.1nm wavelength scanning, which mitigates cross-interference from absorption bands of interferent gases—also referred to as "fingerprint spectroscopy". This enables high-resolution near-infrared absorption measurements. Electron phase-locking technology facilitates the extraction and isolation of gas absorption signatures from photoelectric signals, eliminating the need for a physical reference cell while providing continuous sensor condition monitoring. The EDK TDL 6900 series offers a high-precision, low-detection-limit solution for in-situ gas measurement, featuring high accuracy, selectivity, zero calibration requirement, low cost, and ease of operation.

 

The EDK TDL 6900 series is capable of quantifying trace gases including NH₃, CH₄, CO₂, H₂O, etc., which are critical in various industrial applications. The inherent high sensitivity and wide dynamic range of TDLAS technology enable gas concentration measurements from sub-ppm levels to percentage levels.


Features


  • Exhibits Ultra - high Sensitivity

  • Functional Safety with Real-time Status Monitoring

  • Long Service Life (Over 10 Years)

  • Rapid Response

  • Low Power Consumption Design

  • Low-Cost Solution (No Consumables, Spare Parts, or Recalibration Required)

  • 19 - inch Mounting Bracket

  • Utilization of Optimal Cost - effective Components Ensures the Lowest - cost Sensor Design

  • User-friendly Human-Machine Interface Design

  • Robust Data Storage and Logging Functionality

  • Flexibly Scalable Multi - point Sampling System Architecture

  • Zero - point and Wide - range Calibration Function

  • Automatic Sensor Status Self - diagnostic Function


Measured   Gas

Minimum Detection Limit (MDL)

Typical   Measurement Range

NH3, (H2O) ammonia

(High-Temperature   & High-Humidity Working Conditions)

0.2   ppm

0~20,50,100,500,1000ppm,50%,the   range can be customized

NH3 ammonia

0.1   ppm

0~20,50,100,500,1000ppm,50%,the   range can be customized

Other   gases are customizable

**The   detection limit is at constant temperature, constant pressure, constant humidity   20°C, 1013 hPa, 50±1.5%r.H. Sudden changes in system   temperature result in faster changes in detection limits than changes in   concentration, and the whole process is 220°C with   high temperature tracing

accuracy

±2% of   Reading Value (RV) is based on integral stability (temperature &   pressure).

Span   Drift

Not   more than 2% per annum

Maximum   temperature error

Not   above 0.1 reading/°C

Linearity/Repeatability

<1%FS(multi-point   calibration),<2%FS(Single-point calibration)

Cell   Temperature

Constant   temperature 220°C (temperature can be set)

Display   Resolution

0.001   ppm

Refresh   Rate

Not   less than 1s (can be set, not less than 120s)

T90   Response Time

Not   higher than 1s (@chest capacity 3 L/min).

Ambient Temperature Compensation Range

-10~65°C   (smallest possible temperature fluctuation)

Maximum   Sample Gas Humidity

50% absolute humidity, depending on the   operating conditions, needs to be entered for calibration, and the pressure,   temperature or mixed gas concentration is compensated by diffusion

Maximum   Sample Volume

5L/min;   Calibration at 3 L/min

Power   Supply

VAC220-230/115   50/60 Hz

Size

51.85cmx40.5cmx23cm

 

Weight

Approx.   15kg

Enclosure

IP65   PP alloy suitcase

Explosion   Protection Rating

ExdII   CT4,ExdII CT5, (customizable)

Gas   Path Connection

Swagelok   Φ6 mm

Data   Storage

Built-in   no less than 8G, which can be expanded through USB port

Measurement   method

In-situ   extraction

Dust   removal filtration

Five-stage   filtration, filtration accuracy is not less than 0.2μm

Sampling   Pumps

Built-in   420°C negative pressure sampling pump

Analog   Output

4~20   mA Current Loop (No Isolation)

Port

Ethernet   port, USB port, Bluetooth, Wifi

Display

5.7"   touch screen

Interactive

  

It   can be connected to a mouse, keyboard and printer, and is not less than a   7-inch touch LCD screen

Sampling   Probes

 

0.5m,   1.5m long, 8mm~25mm outer diameter sampling probe greater than 220°C,   stainless steel or PTFE material, can be customized

Sampling   heat trace lines

5m   long 220°C heat tracing pipeline, outer diameter 6mm interface, with no   less than 25μm filtering function, power supply   220VAC, 50Hz, 200W, weight not more than 2.5kg






Copyright © Lightwaves Website Map